Ki Han Kim1, Eunseo Ryu1, Siyoung Park2, Hyobin Lee2, Jaejin Lim3, Tae Soon Kwon4, Duckhee Lee4,5**, and Yong Min Lee1,2,3*김기한1·류은서1·박시영2·이효빈2·임재진3·권태순4·이덕희4,5**·이용민1,2,3*
1Department of Battery Engineering, Yonsei University, Seoul 03722, Republic of Korea 2Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST),Daegu 42988, Republic of Korea 3Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea 4Railroad Safety Research Division, Korea Railroad Research Institute (KRRI), Gyeonggi-do 16105, Republic of Korea 5Department of Transportation System Engineering, University of Science and Technology (UST), Gyeonggi-do 16105, Republic of Korea1연세대학교 배터리공학과, 2대구경북과학기술원 에너지공학과, 3연세대학교 화공생명공학과, 4한국철도기술연구원 철도안전환경본부, 5과학기술연합대학원대학교 교통시스템공학과

본 연구에서는 철도 터널 화재상황 시 고온 열환경에서 승객 대피 임무를 수행하는 피난관제 로봇의 핵심 부품인 리튬이온배터리의 열안전성을 평가하기 위해 시뮬레이션 기법을 사용하였다. 실제 리튬이온배터리 셀로부터 시뮬레이션에 필요한 열적·전기화학적 파라미터 값을 추출하고, 이를 기반으로 개발된 단위 셀 및 모듈 단위의 3D 열-전기화학 모델(Thermo-Electrochemical Model)을 개발하였다. 철도 터널 화재 시 약 250 °C의 고온 노출 상황을 가정하고 리튬이온배터리의 열안전성을 분석하기 위하여 열폭주(Thermal Runaway, TR) 전 단계인 자가발열단계 (Self-Heating Stage, SHS)의 기준온도에 도달하는 시간을 개발 모델로 예측하였다. 특히, 본 연구에 사용된 피난관제 로봇이 250 °C 외부온도에 노출되었을 때 배터리 셀이 SHS 기준온도(132 °C)에 도달하는 데까지 약 4 분이 걸리는 것으로 계산되었고, 이는 실제 화재 상황에서 승객 대피 임무를 수행하는데 매우 부족한 시간이라 볼 수 있다. 따라서, 본 연구는 철도터널용 피난관제 로봇의 전지부 열안전성 확보를 위한 리튬이온배터리 셀 및 모듈의 모델링 플랫폼을 제공하고자 한다.

 

In this study, a simulation technique was used to evaluate the thermal safety of a lithium-ion battery (LIB)—a core component of an evacuation guide robot designed to perform passenger evacuation missions in high-temperature environments during railway tunnel fires. Thermal and electrochemical parameters required for the simulation were extracted from a physical LIB cell, and 3D thermo-electrochemical models for both unit cells and modules were developed. Assuming an exposure to a high temperature of approximately 250 °C during a tunnel fire, the time required to reach the self-heating stage (SHS) temperature—the pre-thermal runaway stage—was calculated through simulation to analyze the LIB’s thermal safety. The results indicated that when the evacuation guide robot was exposed to an ambient temperature of 250 °C, it took approximately 4 minutes for the battery cell to reach the SHS reference temperature (132 °C), representing a very short window to complete passenger evacuation in an actual fire scenario. Therefore, this work provides a useful prognostic thermo-electrochemical model platform to ensure the thermal safety of LIB systems in railway tunnel evacuation guide robots.

Keyword : Lithium-ion Battery, Thermo-Electrochemical Model, Evacuation Guide Robot, Battery Thermal Safety, Digital Twin