Skip Navigation
Skmp to contents

한국전기화학회 한국전기화학회

gnbBg

Vol.6, No.4, November 2003

Micro Capillary Tube 방법을 이용한 430 스테인레스강 틈의 폭변화에 따른 틈부식의 전기화학적 평가An Electrochemical Evaluation on the Crevice Corrosion of 430 Stainless Steel with Variation of Crevice Wide by Micro Capillary Tubing Method
JKES Vol.6, No.4, pp.250~254, November 2003
DOI : 10.5229/JKES.2003.6.4.250
Eun-Young Na나은영
Korea Maritime University한국해양대학교 대학원
this study, the IR drop theory was adopted to explain the initiation of crevice corrosion in the framework of IR drop in crevice electrolyte. Furthermore, the electrochemical polarization was measured to study the mechanism of crevice corrosion for type S
Keyword : IR Drop(Potential drop), Micro capillary tube, Current density, Ferrite stainless steel

Full Text PDF 다운로드

위로가기

COPYRIGHT (C) KECS. ALL RIGHTS RESERVED.

  • 사업자등록번호: 209-82-06548
  • 사업자명: (사)한국전기화학회
  • 대표자: 이재준
  • 주소: 02566 서울특별시 동대문구 왕산로 122(용두동, 한방천하 포스빌 1715호)
  • 대표전화: +82-2-568-9392
  • 자주하는 질문 (FAQ)
  • 전자우편: kecs98@kecs.or.kr (대표)